Model NO.: YJV22
Wire Core Material: Red Copper Wire
Certification: ISO
Model: YJV
Brand: Hufei
Conductor Material: Copper
Jacket: PVC
Armored: Sta or Swa
Nominal Voltage: 21/35-26/35kv
Voltage Test: 73.5kv/91kv
Partial Discharge Test: 1.73 U0
Trademark: Hufei
Transport Package: International Wooden Drum
Specification: CE
Origin: Shanghai
HS Code: 85444911
Model NO.: YJV22
Wire Core Material: Red Copper Wire
Certification: ISO
Model: YJV
Brand: Hufei
Conductor Material: Copper
Jacket: PVC
Armored: Sta or Swa
Nominal Voltage: 21/35-26/35kv
Voltage Test: 73.5kv/91kv
Partial Discharge Test: 1.73 U0
Trademark: Hufei
Transport Package: International Wooden Drum
Specification: CE
Origin: Shanghai
HS Code: 85444911
35 kV or Lower Power Cable with XLPE InsulationThe cable is used to transmit power on the power transmission and distribution line of A.C. 50Hz, rated volt-age 35 KV or lower. By comparison with power cable with PVC insulation, it has not only excellent electric perfor-mance, mechanical performance, heat & aging resistant performance, weather resistant performance, chemical corrosion resistant performance, but also simple structure,light weight, no restriction by laying drop, and high tem-perature allowance for long term working(90ºC) as well.
Executive standard
As section "extruded insulation power cable with rated voltage from 1kV(Um=1.2 kV)to 35kV (Um=40.5 kV)" stipulated in GB/T12706.1-2002~ GB/ T12706.3-2002 or IEC60502-1997 according to the re-quirement of the customer.
Working Condition
1,Long-term working temperature by cable conducto is 90ºC.
2,Max. temperature of cable conductor shall be no more than 250ºC during short circuit (the longest lasting time shall be no more than 5 seconds).
3,Environment temperature for installation is no less than 0ºC.
4,Min bending radium of cable:
It is no less than 15 times that of cable outer diameter for cable with three cores.
It is no less than 20 times that of cable outer diameter for cable with single core.
5,A.C. rated voltage U0/U of cable is 0.6/1kV~26/35kV.
U0: rated A.C. voltage of conductor to earth OR between metallic shielding for cable designing, which is called phrase voltage.
U:rated A.C. voltage between conductors for cable designing, which is called wire voltage.
Um: Max endurable value of "Max system voltage"for cable
Type, Description and Application Occasion
Type |
Description |
Application n |
|
Cu |
Al |
||
YJV |
YJLV |
XLPE insulation PVC sheath power cable |
To be laid indoors, in tunnel, cable furrow or pipe, the cable couldn't bear mechanical force outside |
YJY |
YJLY |
XLPE insulation PE sheath power cable |
|
YJV22 |
YJLV22 |
XLPE insulation, steel tape armor, PVC sheath power cable |
To be laid underground, the cable could bear certain mechanical force, but it couldn't bear great pulling force. |
YJV23 |
YJLV23 |
XLPE insulation, steel tape armor, PE sheath power cable |
|
YJV62 |
YJLV62 |
XLPE insulation, have no the magnetism steel tape armor, PE sheath power cable |
|
YJV32 |
YJLV32 |
XLPE insulation, thin steel-wire armor, PVC sheath power cable |
Be applicable to the well, water inside and fall in the bad soil, the cable cans bear the equal dint outside the machine with pull the dint . |
YJV72 |
YJLV72 |
XLPE insulation, have no the magnetism thick steel-wire armor, PVC sheath power cable |
|
YJV42 |
YJLV42 |
XLPE insulation, thick steel-wire armor, PVC sheath power cable |
Be applicable to the well, underwater with the bottom of sea, the cable cans bear the bigger pressure with lead to pull the dint. |
Note:1: We also produce steel wire armored cross-linked power cable such as YJV32,YJLV32,YJV33,YJLV33 according to the requirement of the customer.
2: Prefi x "ZR" (flame retardant type) shall be added to the original type when flame retardant type cable is needed.
The Figure of Cable Structure
Production Scope
ProductionÂ
 35 kV or Lower Power Cable with XLPE Insulation
The cable is used to transmit power on the power transmission and distribution line of A.C. 50Hz, rated volt-age 35 KV or lower. By comparison with power cable with PVC insulation, it has not only excellent electric perfor-mance, mechanical performance, heat & aging resistant performance, weather resistant performance, chemical corrosion resistant performance, but also simple structure,light weight, no restriction by laying drop, and high tem-perature allowance for long term working(90ºC) as well.
Executive standard
As section "extruded insulation power cable with rated voltage from 1kV(Um=1.2 kV)to 35kV (Um=40.5 kV)" stipulated in GB/T12706.1-2002~ GB/ T12706.3-2002 or IEC60502-1997 according to the re-quirement of the customer.
Working Condition
1,Long-term working temperature by cable conducto is 90ºC.
2,Max. temperature of cable conductor shall be no more than 250ºC during short circuit (the longest lasting time shall be no more than 5 seconds).
3,Environment temperature for installation is no less than 0ºC.
4,Min bending radium of cable:
It is no less than 15 times that of cable outer diameter for cable with three cores.
It is no less than 20 times that of cable outer diameter for cable with single core.
5,A.C. rated voltage U0/U of cable is 0.6/1kV~26/35kV.
U0: rated A.C. voltage of conductor to earth OR between metallic shielding for cable designing, which is called phrase voltage.
U:rated A.C. voltage between conductors for cable designing, which is called wire voltage.
Um: Max endurable value of "Max system voltage"for cable
Type, Description and Application Occasion
Type |
Description |
Application n |
|
Cu |
Al |
||
YJV |
YJLV |
XLPE insulation PVC sheath power cable |
To be laid indoors, in tunnel, cable furrow or pipe, the cable couldn't bear mechanical force outside |
YJY |
YJLY |
XLPE insulation PE sheath power cable |
|
YJV22 |
YJLV22 |
XLPE insulation, steel tape armor, PVC sheath power cable |
To be laid underground, the cable could bear certain mechanical force, but it couldn't bear great pulling force. |
YJV23 |
YJLV23 |
XLPE insulation, steel tape armor, PE sheath power cable |
|
YJV62 |
YJLV62 |
XLPE insulation, have no the magnetism steel tape armor, PE sheath power cable |
|
YJV32 |
YJLV32 |
XLPE insulation, thin steel-wire armor, PVC sheath power cable |
Be applicable to the well, water inside and fall in the bad soil, the cable cans bear the equal dint outside the machine with pull the dint . |
YJV72 |
YJLV72 |
XLPE insulation, have no the magnetism thick steel-wire armor, PVC sheath power cable |
|
YJV42 |
YJLV42 |
XLPE insulation, thick steel-wire armor, PVC sheath power cable |
Be applicable to the well, underwater with the bottom of sea, the cable cans bear the bigger pressure with lead to pull the dint. |
Note:1: We also produce steel wire armored cross-linked power cable such as YJV32,YJLV32,YJV33,YJLV33 according to the requirement of the customer.
2: Prefi x "ZR" (flame retardant type) shall be added to the original type when flame retardant type cable is needed.
The Figure of Cable Structure
Production Scope
ProductionÂ
Â
High Current Terminal Blocks,Panel Terminal Block,Feed Through Terminal Block,Heavy Power Terminal Block
Sichuan Xinlian electronic science and technology Company , https://www.sztmlch.com