Model NO.: XGN66-12
Trademark: dehler
Transport Package: Woood Carton
Origin: Wenzhou, China
HS Code: 8537109090
Company Introduction:
Dehler Technology Co., Ltd. specializes in producing high and low voltage switchgear, box type substation, cable branch box, outdoor vacuum circuit breaker, isolation switch, grounding switch, load switch and low voltage components and other products.
XGN66-12 Metalclad AC Indoor Enclosed Switchgear
 1. General Description
Â
1.1 Application: In the power system of 3.6Â to 40.5kV, for control, protection and monitoring.VCBs produced
Â
By Dehler or VCBs produced by other manufactures could be installed in the switchgear panel.
Â
1.2 Standards : IEC 62271-200
Â
1.3 Parameters: Rated voltage: 3.6V
Â
1.4 Rated current: 630-5000AÂ
Â
1.5 Rated short-circuit breaking current: 16kA
Â
Â
Â
2.Features:
Â
2.1.Compact design
Â
2.2.Easy operation and installation
Â
2.3.Reliable interlock
Â
2.4.Less Maintenance
Â
Â
3.Technical Data
Â
No. | Item | Unit | Data | |
3.1 | Rated voltage | kV | 3.6,7.2,12,24,40.5 | |
3.2 | Rated current of circuit breaker | A | 630,1250,1600,2000,2500,3150,4000,5000 | |
Rated current of switchgear | A | 630,1250,1600,2000,2500,3150,4000,5000 | ||
3.3 | Rated frequency | Hz | 50 | |
3.4 Â |
Rated short-circuit breaking current | kA | 16,20,25,31.5,40,50 | |
Rated short-time withstand current | kA | 16,20,25,31.5,40,50 | ||
Rated short circuit continuous time | s | 4 | ||
3.5 | Rated peak withstand current | kA | 40,50,63,80,100,125 | |
Rated short-circuit closing current(peak) | kA | 40,50,63,80,100,125 | ||
3.6 | Rated insulation level: 1min power frequency withstand voltage | kV | 24,32,42 between poles, pole to earth | |
kV | 24,32,48 between open contacts | |||
3.7 | Rated insulation level: Lighting impulse withstand voltage(peak) | kV | 40,60,75 between poles, pole to earth | |
kV | 46,70,85 between open contacts | |||
3.8 | Rated power frequency withstand voltage | kV | 95/1min | |
3.9 | Protection level | Switchgear shell | Â | IP3X |
Compartments(door opened) | Â | IP2X when the CPT and CB doors are open. |
Â
Note: 1.The short circuit capacity of the current transformer should be separately considered.
Â
      2. See technical parameters of ZN63A(VS1)-12 in related product of our company.
Â
We also supply the following switchgears:
Rated votlage 40.5KV switchgear(for 33KV system)
KYN61-40.5 withdrawout metal-clad and metal-enclosed switchgear
KYN10-40.5AC drawout metal clad switchgearÂ
KYN1-40.5 AC withdrawable metal-clad enclosed switchgearÂ
XGN-40.5 fixed AC metal-enclosed switchgearÂ
GBC-40.5 Handcar HV switchgearÂ
Rated voltage 24KV switchgear(for 22KV,20KV, 15KVsystem)
KYN-24  withdrawable metal-clad switchgear
HRM6-24 Ring net SF6 circuit breaker switchgear ( for 22KV,20KV, 15KVsystem )
Â
Rated votlage 12KV switchgear(for 11KV,10KV,6.6KV system)
KYN28A-12 withdrawable metal-clad enlosed switchgear
XGN-HKGN8-12 Fixed metal clad enclosed switchgear  (for 11KV,10KV,6.6KV system)
Â
HXGN-12 Ring Net Vacuum circuit breaker switchgear ( for 11KV,10KV,6.6KV system )
Â
XGN15-12  Ring Net SF6 circuit breaker switchgear (for 11,10,6.6KV system)
Â
Rated voltage 0.4KV low voltage switchgear(380V,400V,433v,440V system)
Â
GCK LV withdrawable switchgear
Â
GCS LV withdrawable switchgear
Â
HMNS LV withdrawable switchgear
Â
GGD LV distribution cabinet
Â
XL-21 Power distribution box
Â
 MOTO Start swichgearÂ
Â
Modula 630K sersies of standard LV distribution box
Â
plus 2.0 LV switchgear
Â
GZDW series of microcomputer monitoring high-frequency DC switchgear
Â
Soft start switchgear
Â
Residential, customized power distribution box
Â
PZ30, PZ40 distribution box
Â
outdoor mobile box
Â
Capacitance compensation box
Â
The other switchgear (from 0.4KV to 33KV)We can OEM , ODM for you.)
Â
Langrui Energy (Shenzhen) Co.,Ltd , https://www.langruienergy.com