1. Standard: IEC60227, HD22.4, NFC-32-12-4.
2. Voltage: 450/750V, 300/500V,300/300V
3. Conductor: Copper
4. Construction: Solid, Stranded wires, flexible
5. Numer of Cores: single core, two cores, 3 cores, multi-cores,Â
6. Material of insulation: PVC,EPR.
7. Insulation: PVC
8. Cross Section area of conductor: 0.5mm2, 1mm2, 2mm2, 1.5mm2, 6mm2, 10mm2..........300mm2
Â
Type | Name |
BV | Copper conductor PVC insulated cable |
BVR | Copper conductor PVC insulated flexible cable |
BVV | Copper conductor PVC insulated PVC sheathed round cable |
BVVB | Copper conductor PVC insulated PVC sheathed Flat Cable |
RVS | Copper conductor PVC insulated stranded cable for flexible connecting |
Structure of Product
1.Conductor
2.Insulation
3.Sheath
Application
It applies to electrical appliance, instrument and telecom device with rated voltage up to and including 450/750V.
The main features of the flame retardant PVC cable or wire is hard to get fair or that the continuous burning of cables is very limited when it is on fire. It applies to the places with special demands for flame retardant property. Flame retardant cable is classified as class A, B or C. Among the 3 classes, class A is the best in aspect of flame retardance.Â
Fire-resistance cable can operate normally for some time when it is burning except that it can transmit electrical power under normal condition. It is used in the places with special demands for fire resistance property.Â
The Main Features
1. Rated voltage U0/U is 450/750V, 300/500V, or 300/300V.
Â
2. Permissible continuous working temperature of cable conductor
--for type of cable RV-90 and BV-90, the temperature should be not more than 90ºC
--for others, the temperature should be not more than 70ºC.
3. Ambient temperature should be not less than 0ºC, and permissible bending radius of cable for fixed connecting should be as follows during installation.
Â
4. Flame retardant cable should pass the test of bunched cables or wires under fire conditions which is described in the standards of GB/T18380.3-2001.
Â
5. Fire resistant cable should pass the test of fire resistant stipulated in the standards of GB/T19216.21-2003.
Key Technical Parameter
60227 IEC 01(BV) Â GB/T5023-2008
Nominal cross-Â section mm2 |
   Conductor Type |
Upper limit Of O.D.         mm |
Max.D.C.  resistance at 20ºC Ω/km     |
Min.insulation  resistance    at 70ºC MΩ·km |
 Approx. ampacity A |
 Reference weight  of cable kg/km |
1.50Â | 1 | 3.2Â | 12.1 | 0.011Â | 25 | 20.0Â |
1.50Â | 2 | 3.3Â | 12.1 | 0.010Â | 25 | 21.5Â |
2.50Â | 1 | 3.9Â | 7.41 | 0.010Â | 34 | 31.8Â |
2.50Â | 2 | 4.0Â | 7.41 | 0.009Â | 34 | 34.8Â |
4.00Â | 1 | 4.4Â | 4.61 | 0.0085Â | 44 | 46.8Â |
4.00Â | 2 | 4.6Â | 4.61 | 0.0077Â | 44 | 50.3Â |
6.00Â | 1 | 5.0Â | 3.08 | 0.0070Â | 58 | 66.50Â |
6.00Â | 2 | 5.2Â | 3.08 | 0.0065Â | 58 | 71.00Â |
10 | 2 | 6.7Â | 1.83 | 0.0065Â | 79 | 116.0Â |
16 | 2 | 7.8Â | 1.15 | 0.0050Â | 111 | 180 |
25 | 2 | 9.7Â | 0.727 | 0.0050Â | 146 | 277 |
35 | 2 | 10.9Â | 0.524 | 0.0040Â | 180 | 375 |
50 | 2 | 12.8Â | 0.387 | 0.0045Â | 282 | 536 |
70 | 2 | 14.6Â | 0.268 | 0.0035Â | 281 | 706 |
95 | 2 | 17.1Â | 0.193 | 0.0035Â | 344 | 977 |
120 | 2 | 18.8Â | 0.153 | 0.0032Â | 397 | 1231 |
150 | 2 | 20.9Â | 0.124 | 0.0032Â | 456 | 1503 |
185 | 2 | 23.3Â | 0.0991 | 0.0032Â | 519 | 1870 |
240 | 2 | 26.6Â | 0.0754 | 0.0032Â | 592 | 2457 |
300 | 2 | 29.6Â | 0.0601 | 0.0030Â | 685 | 3053 |
400 | 2 | 33.2Â | 0.0470Â | 0.0028Â | 799 | 3948 |
Company Building & offices
Factory & Wokshop
CertificatesÂ
Customers
 Basic Information
1. Standard: IEC60227, HD22.4, NFC-32-12-4.
2. Voltage: 450/750V, 300/500V,300/300V
3. Conductor: Copper
4. Construction: Solid, Stranded wires, flexible
5. Numer of Cores: single core, two cores, 3 cores, multi-cores,Â
6. Material of insulation: PVC,EPR.
7. Insulation: PVC
8. Cross Section area of conductor: 0.5mm2, 1mm2, 2mm2, 1.5mm2, 6mm2, 10mm2..........300mm2
Â
Type | Name |
BV | Copper conductor PVC insulated cable |
BVR | Copper conductor PVC insulated flexible cable |
BVV | Copper conductor PVC insulated PVC sheathed round cable |
BVVB | Copper conductor PVC insulated PVC sheathed flat cable |
RVS | Copper conductor PVC insulated stranded cable for flexible connecting |
Structure of Product
1.Conductor
2.Insulation
3.Sheath
Application
It applies to electrical appliance, instrument and telecom device with rated voltage up to and including 450/750V.
The main features of the flame retardant PVC cable or wire is hard to get fair or that the continuous burning of cables is very limited when it is on fire. It applies to the places with special demands for flame retardant property. Flame retardant cable is classified as class A, B or C. Among the 3 classes, class A is the best in aspect of flame retardance.Â
Fire-resistance cable can operate normally for some time when it is burning except that it can transmit electrical power under normal condition. It is used in the places with special demands for fire resistance property.Â
The Main Features
1. Rated voltage U0/U is 450/750V, 300/500V, or 300/300V.
Â
2. Permissible continuous working temperature of cable conductor
--for type of cable RV-90 and BV-90, the temperature should be not more than 90ºC
--for others, the temperature should be not more than 70ºC.
3. Ambient temperature should be not less than 0ºC, and permissible bending radius of cable for fixed connecting should be as follows during installation.
Â
4. Flame retardant cable should pass the test of bunched cables or wires under fire conditions which is described in the standards of GB/T18380.3-2001.
Â
5. Fire resistant cable should pass the test of fire resistant stipulated in the standards of GB/T19216.21-2003.
Key Technical Parameter
60227 IEC 01(BV) Â GB/T5023-2008
Nominal cross-Â section mm2 |
   Conductor Type |
Upper limit Of O.D.         mm |
Max.D.C.  resistance at 20ºC Ω/km     |
Min.insulation  resistance    at 70ºC MΩ·km |
 Approx. ampacity A |
 Reference weight  of cable kg/km |
1.50Â | 1 | 3.2Â | 12.1 | 0.011Â | 25 | 20.0Â |
1.50Â | 2 | 3.3Â | 12.1 | 0.010Â | 25 | 21.5Â |
2.50Â | 1 | 3.9Â | 7.41 | 0.010Â | 34 | 31.8Â |
2.50Â | 2 | 4.0Â | 7.41 | 0.009Â | 34 | 34.8Â |
4.00Â | 1 | 4.4Â | 4.61 | 0.0085Â | 44 | 46.8Â |
4.00Â | 2 | 4.6Â | 4.61 | 0.0077Â | 44 | 50.3Â |
6.00Â | 1 | 5.0Â | 3.08 | 0.0070Â | 58 | 66.50Â |
6.00 | 2 | 5.2 | 3.08 | 0.0065 | Audio Video Cable:Video cable, referred to as video cable, is composed of video cable and connector. Among them, video cable is coaxial shielded cable with characteristic impedance of 75 Ω (Ω). Common specifications are divided into - 3 and - 5 according to wire diameter, single core wire and multi-core wire according to core wire, common specifications of connector are divided into pressure joint and welding joint according to cable end connection mode, and equipment There are BNC (commonly known as bayonet) and RCA (commonly known as lotus head). Audio cable, referred to as audio cable, is composed of audio cable and connector. The audio cable is generally a dual core shielded cable, and the common connectors are RCA (commonly known as lotus head), XLR (commonly known as XLR head) and trsjacks (commonly known as pen plug). Audio Video Cable ShenZhen Antenk Electronics Co,Ltd , https://www.antenk.com |